Consumer trends in the field of laser and phototherapy beauty devices: a shift from the past "strong filling/over-plumping" to "skin architecture reconstruction" and "invisible lifting".
In clinical practice and the market, when doctors say "CoolPeel laser," they are referring to the following three specific carbon dioxide laser devices:
* **SmartXide Tetra CO₂** (classic flagship model)
* **Tetra PRO** (a newly upgraded, faster flagship model launched in 2025/2026)
***Boslaser High Power Fractional CO2 Laser (a more cost-effective alternative to major brands from China, suitable for distributors)
Why are only these three devices suitable for CoolPeel?
Traditional carbon dioxide lasers (10600nm) are hailed as the "gold standard" for wrinkle and acne scar removal, but due to the significant residual heat, the face often becomes covered in scabs and oozing fluid after treatment, requiring a grueling 1-2 week recovery period.
1. **Exclusive H-Pulse (High-Peak Ultrashort Pulse):** The SmartXide Tetra emits an extremely short pulse with a very high instantaneous energy peak. 1. It vaporizes damaged epidermal tissue directly within microseconds, **ending the pulse before the heat can be conducted to surrounding healthy tissue.**
2. **No lingering heat:** Because the surrounding tissue is almost completely unburned, the skin will not experience extensive redness, swelling, or pus after the procedure. It will only show redness like a mild sunburn for 1-2 days, followed by slight flaking like fine sand on days 3-5.
3. **These three devices all have two modes. The first is a gentle mode or superficial mode (CoolPeel mode):** Superficial ablation. No numbing cream is needed, the procedure takes 10 minutes, and recovery takes 1-2 days. It primarily targets minimizing pores, brightening skin tone, and reducing the appearance of fine lines. It's very popular among working professionals in the US who prefer to have it done on Fridays so they can wear light makeup to work on Monday. The second mode is a hardcore mode (traditional fractional CO₂ mode) or deep ablation mode. This requires deep anesthesia and has a 5-7 day downtime. Primarily targets stubborn and severe pitted acne scars, deep static wrinkles, and facial tightening.
4. The Golden Duo in the Market: Ultimate Duo combination therapy
Due to CoolPeel's excellent heat control, clinics frequently combine **Boslaser CO₂ (CoolPeel)** with DerRF gold microneedling radiofrequency in a single treatment (known in the US as the **Ultimate Duo** combination therapy). DerRF gold microneedling radiofrequency deeply tightens the fibrous network, while Boslaser CO₂ CoolPeel polishes the epidermis. The combined effect achieves a comprehensive rejuvenation result greater than the sum of its parts (1+1>2), with a very short recovery period.

What is the peak power and pulse rate required to avoid thermal damage?
Boslaser CO₂ Laser CoolPeel is not completely "zero thermal damage," but rather achieves "extremely low and controllable superficial epidermal thermal damage," thus preventing "lingering heat" from spreading to surrounding healthy tissue.
Carbon dioxide (CO₂) lasers have an extremely high absorption rate for moisture. To achieve complete vaporization and ablation without burning surrounding tissue, a core principle of laser physics must be met—the pulse duration must be shorter than the skin's Thermal Relaxation Time (TRT).
The TRT of various structures in the epidermis is approximately within 1 millisecond (1000 microseconds). If the pulse ends within this time, the heat will not have enough time to conduct and diffuse.
### 1. What is the Pulse Duration?
* **Core Value:** Approximately 200 to 350 microseconds (μs).
* **Physical Meaning:** 1 microsecond equals one millionth of a second. Boslaser's CO₂ Laser CoolPeel's H-Pulse (High Pulse) mode compresses the time between each skin impact to **0.2 to 0.35 milliseconds**.
* This speed is far below the skin's epidermal thermal relaxation time limit of approximately 1 millisecond. The laser cuts in like lightning, instantly vaporizing the target tissue and carrying it away with the plume of smoke. The surrounding cells don't even have time to "react and heat up" before the pulse is shut off.
### 2. What is the Peak Power?
* **Core Value:** Up to 100 watts (W) or more.
* **Physical Significance:** Many traditional CO₂ lasers, while having an average power of 30W-40W, have "slow and steady" pulses (lasting only a few milliseconds) with very low peak power, resulting in the skin being continuously "slowly baked."
* The Boslaser CO₂ Laser, however, uses a radio frequency excitation mechanism within its handpiece that can instantly boost the power to a very high peak of hundreds of watts within an extremely short microsecond time, achieving an instantaneous burst of power.

### 3. The Perfect Ratio of "Low Energy"
High power and short pulses alone are not enough. The core of Boslaser CO₂ Laser CoolPeel's ability to achieve truly painless, bloodless treatment without anesthesia lies in its very low total energy per point (typically controlled at 5mJ - 15mJ per point). Its working process is as follows:
[Instantaneous High-Pulse Release] + High Peak Power (>100W) + Ultra-Short Duration (<350μs) = Precisely vaporizes only the outermost layer of keratinocytes and cells. Because thermal damage is strictly confined within the micron-level vaporization column, the surrounding healthy bridge skin is completely unaffected by "excess heat." Therefore, it can break through the grueling recovery period of traditional CO₂ lasers, which involves "pus discharge, thick scab formation, and two weeks of downtime," allowing the skin to show only slight redness and a dry, flaky feel similar to sandpaper within 24 to 48 hours.
Scan the QR code to read on your phone
Beijing Super laser Technology Co., Ltd.
Beijing Superlaser Technology Co., Ltd
Professional Aesthetics & Medical Laser Equipment Manufacturer. FDA/Medical CE/TUV / ISO13485 Approved. 15-Year Experience in OEM/ODM Service.
2 floor,building3, No.2 zhongfu street,
xihongmen town,daxing district,Beijing
Newsletter
Copyright © Beijing Super laser Technology Co., Ltd. All rights reserved. 京ICP备10032915号
Privacy Policy. Powered By: www.300.cn
Send message
Please fill out the form below and we will get back to you as soon as possible.